RT_BSL_KIN_GX_P1P2L1L2_IGU

<- RTNet Template Input Files Top

Processing and Solutions

Two real-time UNAVCO PBO stations (P395 and P367) used for real-time baseline processing. The baseline length between two stations is about 51.2 km.

See UNAVCO PBO station map for information on UNAVCO PBO stations.

Coordinate Estimate
Real-time coordinate solution for UNAVCO P367 station relative to P395 station. The last real-time test processing was performed on April 11, 2013.



Sample data and Setting

Item/Parameters Notes and Setting
Processing Baseline RTK (1Hz)
Purpose Real-time deformation monitoring of the coordinate.
Stations UNAVCO PBO stations: P395 and P367
  => Link to UNAVCO PBO station map
(Please use the template file by replacing the stations).
Real-time Processing Start time: MJD 56394.057 (2013/04/11)
Used data GPS phase L1/L2, code P1/P2
Get data UNAVCO data is open to registerd users (please see Data in UNAVCO website.
Satellite products IGU orbit (predcited part) stored (synced with IGS server) in local server is used for real-time processing.
Setting in processing P395 is fixed, and coordinate of P367 is estimated with 1Hz.
Constrain A priori coordinate 100m, Coordinate change 100m/s, ZTD for P367 1e-5 m/s
Processing cost N/A
Validation Repeatability of coordinate solutions (reference is a priori coordinate).




RTES Setting for Real-time processing

Some files for real-time data processing have detailed information on GNSS stations. Special password is required to download these files (shadowed boxes).

Item/Parameters Files Notes and Setting
Start RTES rtes_v4_unavco_2013-04_xml rt_epoch_server.sh -I tes_v4_unavco_2013-04_xml > /dev/null 2>&1 &
Add stations start_all_unavco_2013-04_xml rtes_batch_v4 -H 127.0.0.1 -p 6100 -I start_all_unavco_2013-04_xml