PP_PPP_STATIC_GF_L3_IGR

<- RTNet Template Input Files Top

Processing and Solutions

GEONET 0332 and 0335 stations.

Coordinate Estimate
Station   dN     dE     dH
0332    -0.0069 0.0013 0.0174
0335    -0.0047 0.0014 0.0145 
Differece of coordinate between RTNet estimate and official coordinate for GEONET from GSI. Please note that RTNet solution is valid at the end of the epoch, and daily GNSS solution is usually valid at the middle of the processing time-window.



Sample data and Setting

Item/Parameters Notes and Setting
Processing PPP processing
Purpose Precise coordinate determination
Stations GEONET stations 0332 and 0335
(Please use the template file by replacing the stations).
Processing time window 2011/07/03 00:00~24:00 GPST
(Please use the template file by cahnging the time-window setting).
Used data GPS+GLONASS phase L3 (IF: Ionosphere free) , 5 min. processing
Get data Redistribution is restricted.
Please your own observation data or get data from GSI.
Satellite products IGR orbit and high-rate 5 min. clock (any standard products can be used, see products available publicly.
Setting in processing PPP static processing
Constrain A priori coordinate 10m, ZTD 1e-5 m/s
Processing cost About 10 seconds
Validation Compare RTNet coordinate solution with those from other software and/or IGS SINEX data. Please note that PPP processing is sensitive with modeling in the processing (earth model, instrument model), and differences of the modeling and parameter setting can couase differences of the coordinate solutions.